You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
Hi,
I've frequently encountered an error while using Display_Probe_Track.m. It's often the case that not all probes (up to 6, so below 11) are displayed in Brain View due to this error:
Error using yyaxis 3-D views are not supported with yyaxis. Change the view to 2-D with view(2).
Error in plotDistToNearestToTip (line 224) yyaxis left
Error in Display_Probe_Track (line 225) borders_table = plotDistToNearestToTip(m, p, av_plot, st, probe_length_histo, error_length, active_site_start, distance_past_tip_to_plot, show_parent_category, show_region_table, plane); % plots confidence score based on distance to nearest region along probe
I've looked at plotDistToNearestToTip.m and indeed it features the yyaxis function used twice, although MATLAB does not support plotting multiple axes in 3-D view. When "yyaxis left" and "yyaxis right" are deleted, then all probes are loaded correctly, but that completely messes up the 3-D Brain View.
Thanks!!
The text was updated successfully, but these errors were encountered:
Hi,
I've frequently encountered an error while using Display_Probe_Track.m. It's often the case that not all probes (up to 6, so below 11) are displayed in Brain View due to this error:
Error using yyaxis
3-D views are not supported with yyaxis. Change the view to 2-D with view(2).
Error in plotDistToNearestToTip (line 224)
yyaxis left
Error in Display_Probe_Track (line 225)
borders_table = plotDistToNearestToTip(m, p, av_plot, st, probe_length_histo, error_length, active_site_start, distance_past_tip_to_plot, show_parent_category, show_region_table, plane); % plots confidence score based on distance to nearest region along probe
I've looked at plotDistToNearestToTip.m and indeed it features the yyaxis function used twice, although MATLAB does not support plotting multiple axes in 3-D view. When "yyaxis left" and "yyaxis right" are deleted, then all probes are loaded correctly, but that completely messes up the 3-D Brain View.
Thanks!!
The text was updated successfully, but these errors were encountered: