4.0.3
- Always show BLE error info
- Update dependencies
-
4.0.2
- Fix Module Loading Error on macOS
-
4.0.1
- Fix Module Loading Error
-
4.0.0
- The node category is now
Network
rather thanInput
andOutput
. - Improve stability on Linux by introducing BlueZ 5 D-Bus API
- On Linux, this node is no longer dependent on the HCI socket library, which has lots of problematic issues that caused inconsistent results with old BlueZ CLI tools.
- Note that when Node-RED process is run by non-root user, add the user to
bluetooth
group so to access BlueZ D-Bus API. For example, runsudo usermod -G bluetooth -a pi
prior to starting the process if it's run bypi
user. - BlueZ's BLE scanning seems to detect devices having
random
address type. But not sure if such devices work with this node properly. - Tested on Raspbian (4.19.97-v7l+) and Raspberry Pi 3/4.
- With the following packages
- bluez 5.50-1.2~deb10u1
- bluez-firmware 1.2-4+rpt2
- With the following packages
- Improve BLE Device Scanning UI/UX
- Check
BLE Scanning
in order to start scanning, andScan Result
select box will be fullfilled automatically whenever devices are found. The update will be performed every 10 seconds. The first scan result will appear after 5 seconds since the scanning starts. See the updated README document for detail.
- Check
GENERIC_BLE_TRACE
environment variable is no longer working. UseDEBUG
environment variable instead.DEBUG=node-red-contrib-generic-ble:index
is compatible withGENERIC_BLE_TRACE=true
.DEBUG=node-red-contrib-generic-ble:*
will output all trace logs within the project.DEBUG=node-red-contrib-generic-ble:index:api
will output all API endpoint access logs.DEBUG=node-red-contrib-generic-ble:noble:*
will output all trace logs undersrc/noble
modules.
- The node category is now
-
3.1.0
- Support Node.js v10.x LTS (Fix #14 and #17)
-
3.0.0
- Refactor entire architecture
- Peripheral connections are retained until it disconnects
- Characteristic subscriptions are retained while the ongoing flows are running (will be unsubscribed on stopping them though)
- The max number of concurrent BLE connections is 5 or 6 according to this document
-
2.0.4
- Fix an issue where this node don't work with [email protected]
-
2.0.3
- Fix an issue where noble looses a reference to a peripheral after it is disconnected
-
2.0.2
- Fix an issue where Write operation cannot be performed properly (#4)
-
2.0.1
- Fix an issue where
Select from scan result
failed to list characteristics
- Fix an issue where
-
2.0.0
- Add
Poll Notify Events
message support so that Generic BLE out node can start to subscribe the given characteristic events - Support characteristic query by one or more uuids
- Add
Mute Notify Events
toGeneric BLE
config node for this node to avoid unnecessary device connection for event subscription - Replace
RED.log
functions with node logging functions as possible to offer precise logging control via UI - Add
Operation Timeout
toGeneric BLE
config node to set the waiting time for Read/Write/Notify response per characteristic rather than per device GENERIC_BLE_OPERATION_WAIT_MS
is introduced for defaultOperation Timeout
value- Remove
Listening Period
fromGeneric BLE
config node GENERIC_BLE_NOTIFY_WAIT_MS
is removed
- Add
-
1.0.2
- Improve README
- Add an example flow file available from the editor UI
-
1.0.1
- Fix an issue where custom characteristics cannot be listed on the Generic BLE config node dialog
-
1.0.0
- Fix an issue where some devices cannot be discovered within a specific time window even after they can be connected
- Fix an issue where the Scan Result select widget didn't show the same item as the stored device info
- Update Scan Result option list whenever Local Name is resolved
- Improve stability by fixing minor bugs
-
0.1.0
- Initial Release (alpha)
node-red
keyword is not yet added