forked from tenss/bench_optics
-
Notifications
You must be signed in to change notification settings - Fork 2
/
custom_compact_2p.tex
249 lines (195 loc) · 11.3 KB
/
custom_compact_2p.tex
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
%%%% Load the document class and packages %%%%
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
\documentclass[a4paper]{report}
\usepackage{epsfig} % to insert PostScript figures
\graphicspath{
{figs_compact2p/}
}
%Change figure names
\renewcommand{\figurename}{Fig}
\usepackage[bf,footnotesize]{caption} % make captions small and label bold
\addtocounter{chapter}{1} %Because starting at zero is silly
\makeatletter
\renewcommand{\thesection}{\@arabic\c@section}
\renewcommand{\thefigure}{\@arabic\c@figure}
\makeatother
\usepackage[a4paper,margin=2.7cm,tmargin=2.5cm,bmargin=2.5cm]{geometry}
\usepackage{textcomp} % To make nice degree symbols and others\usepackage[bf,footnotesize]{caption} % make captions small and label bold
\usepackage{wrapfig}
%to produce the clickable references along the left in Acroread. This
%package must be included last.
\usepackage[ps2pdf,bookmarks=TRUE]{hyperref}
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
%%%% Hypertext references for Acrobat %%%%
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
\hypersetup{
pdfauthor = {SWC},
pdftitle = {Custom Two Photon},
pdfkeywords = {optics, lenses, two photon, imaging, PMT, microscope},
pdfcreator = {LaTeX with hyperref},
pdfproducer = {dvips + ps2pdf}
}
\begin{document}
%set the number of sectioning levels
\setcounter{secnumdepth}{2}
\begin{center}
\textbf{\Large{Building a Custom Two Photon Microscope}}
\end{center}
\section{Introduction}
It is time to put together everything you've learned so far and build a two photon microscope.
The microscope you will be building was designed specifically for this optics course and has the following features:
\begin{itemize}
\item A small footprint so two microscopes can be built simultaneously on a small optical table.
\item Modular design. e.g. the scanner relay optics can be assembled separately and just dropped into the microscope.
\item Light path remains low to the table for safety.
\item Low cost: almost all parts readily available from ThorLabs.
\end{itemize}
\section{IMPORTANT SAFETY INFORMATION}
Read this laser safety information before beginning.
The following information should have been conveyed to you verbally.
Please ask if you did not receive verbal instruction or if you have questions about laser safety.
You will be working with a high energy pulsed laser capable of instantly blinding you should it enter your eye.
During operation of the microscope the laser will be tuned to 920 nm which is invisible.
Despite being invisible, the laser remains equally bright and equally dangerous.
Be very cautious around the set up:
\begin{itemize}
\item Wear eye protection and use IR viewing cards as appropriate.
\item Always be aware of the location of the beam and ensure everyone else in the room is also aware.
\item Remove watches, jewelry, etc. Avoid directing the beam at shiny surfaces which could reflect it at unpredictable angles.
\item Reduce laser power during alignment and tune the laser to visible wavelengths when possible.
\item Shutter the beam when not using it.
\item Take particular care where the beam is directed upwards, such as in the periscope.
\item The scanners can deflect the beam by $>20$ degrees depending on the command signal. Ensure the mirrors are static and zeroed before routing the beam into the scan head for the first time.
\item Stand behind the scanners whilst the microscope is scanning.
\item Use beam blocks where appropriate to keep the beam within your work area.
\end{itemize}
\clearpage
\section{General Plan}
Fig.~\ref{fig:layout} (left) shows the layout of key components on the optical table.
The beam leaves the laser and enters a half-wave plate and polarizing beam-splitter cube that we will use to control laser power.
The shutter is used to gate the beam for safety and not to fry the sample when you are not scanning.
The beam proceeds to a beam expander and then on to the microscope.
Fig.~\ref{fig:layout} (right) is a CAD model depicting the completed microscope.
You will complete assembly of the microscope and align the beam through the scan optics.
\begin{figure}[h]
\center
\includegraphics[width=3in]{2p_table_layout.eps}
\includegraphics[width=3in]{completed_2p.eps}
\caption{Left: Layout of the main lightpath. Only key components are shown. Right: CAD model of the completed microscope (minus emission detection path).}
\label{fig:layout}
\end{figure}
\clearpage
\subsubsection{Main microscope assembly}
The skeleton of the microscope frame Fig.~\ref{fig:frame} (left) is already assembled and mounted on its support pillars Fig.~\ref{fig:frame} (right).
The optional SM2 cage plate (shown in purple) can temporarily be used to support the cage if you feel this is necessary.
\begin{figure}[h]
\center
\includegraphics[width=2.53in]{frame.eps}
\includegraphics[width=2.18in]{mount_frame.eps}
\caption{Microscope frame (left) alone and mounted on support pillars (right). Support pillars shown in red. Temporary and optional brace for the cage system shown in purple.}
\label{fig:frame}
\end{figure}
\subsubsection{Periscope}
The periscope (Fig.~\ref{fig:periscope}) brings the beam up into the scan head and has already been assembled but not attached to the microscope frame.
Consider how the beam should be fed into the microscope from the beam expander.
Depending on how the light path is arranged you might wish to alter the orientation of the upper and lower mirrors.
There is an extra alignment iris in the periscope box, you can place this wherever you think is most helpful.
You can now attach the periscope to the microscope and support it with the components shown in red.
Do this by:
\begin{itemize}
\item Slightly loosening the clamp to the large periscope support post.
\item Attach the periscope to the microscope frame and tighten all the cage rod set screws
\item Clamp the periscope support post to the table.
\item Tighten the periscope clamp on the post.
\end{itemize}
Ensure the periscope is vertical and not tilted and that the scanner enclosure is square with respect to the cage system.
Once bolted to the table, the periscope will also stop the scanners from rotating in the SM2 cage plate to which they are screwed.
\begin{figure}[h]
\center
\includegraphics[width=1.18in]{periscope_01.eps}
\includegraphics[width=1.08in]{periscope_02.eps}
\caption{Periscope assembly. Support structures shown in red.}
\label{fig:periscope}
\end{figure}
\clearpage
\subsubsection{Aligning the beam with the frame}
You are now in a position to feed the the beam into the scanners.
\textbf{Be cautious feeding the beam into the periscope: perform this step with assistance}.
Use the provided alignment tools and your beam alignment skills to get the beam traveling straight down the middle of the microscope frame.
\textbf{Before beginning, ensure the scanners are powered and zeroed. Always be aware of where the beam is located.}
\subsubsection{Scan Optics}
You will now finish assembling the scan lens and tube lens module, assembled as shown in Fig.~\ref{fig:scan_optics}.
Avoid touching the lens surfaces.
Once assembled, you can drop the unit into the microscope frame.
Ensure the beam exits the assembly collimated.
Take care with the CDA1 drop-in hangers: tighten gently and only once they are clamped onto a rod.
What is the total expansion of the beam?
\begin{figure}[h]
\center
\includegraphics[width=4.5in]{scan_optics_01.eps}
\includegraphics[width=4.5in]{scan_optics_02.eps}
\caption{Scan and tube lens module.}
\label{fig:scan_optics}
\end{figure}
\clearpage
\subsubsection{Completing the excitation path}
If you had an SM2 cage plate (the one highlighted in purple) supporting the frame, you will need to remove it to add the dichroic cube (Fig.~\ref{fig:dichroic_holder}).
Think before you do this, however.
How far should the scanner relay optics be from the scanners and how far from the tube lens should the dichroic cube be mounted?
The path of the beam through the cube is depicted in Fig.~\ref{fig:dichroic_holder} as a red line.
To help you with this step, you can move the scanners over a small scan angle whilst looking at the the beam motion.
Use ScanImage for this, as it is has been configured to avoid large scan angles.
\textbf{Be cautious: the beam might still spill out of the scan head. Stand behind the scanners and perform this step with assistance}.
Finally, is the beam exiting the cube traveling directly downwards and so on-axis with the objective we will add?
Use two rods and the spring-loaded SM1 target to check.
\begin{figure}[h]
\center
\includegraphics[width=2.0in]{dichroic_cube.eps}
\includegraphics[width=2.0in]{laser_path_through_cube.eps}
\caption{Dichroic cube. Image on the right shows the path of the laser beam through the component.}
\label{fig:dichroic_holder}
\end{figure}
Once you are satisfied with the alignment, you can try scanning a fluorescent plastic sample card and confirming by eye that you get fluorescence whilst the beam is moving over the sample:
\begin{itemize}
\setlength\itemsep{0.15em}
\item Insert the 40x objective.
\item Add the 3-axis stage under the objective.
\item Place a Chroma fluorescent sample card on the stage and carefully bring it up to the objective. Working distance is 2 or 3 mm.
\item Use water as the immersion medium.
\item Use a low laser power and a suitable wavelength.
\item Start scanning and focus until you see fluorescence.
\end{itemize}
\clearpage
\subsubsection{Adding the emission path}
You now have a functioning excitation path, but you need a detector in order to get an image.
You will now to add a PMT with appropriate relay optics in order to capture the fluorescence on the PMT surface.
A schematic depicting the path the emitted light will take is shown in Fig.~\ref{fig:dichroic_holder_paths}.
Think carefully what lens or lenses you need to add before the PMT.
Hint: what should be conjugate with the PMT?
What other optical element do you need to add before the PMT?
The PMT is \textbf{delicate}.
Do not expose it to even room light when powered on, as this will damage the photocathode.
Get assistance to power the PMT and hook up the amplifier.
\begin{figure}[h]
\center
\includegraphics[width=3.1in]{cube_emission_cutout.eps}
\caption{Path of the emitted light through the dichroic cube. The cube's side-plate is removed to show the dichroic mirror itself. The illustration also shows the objective (transparent) and PMT holder (to the far right).}
\label{fig:dichroic_holder_paths}
\end{figure}
\subsubsection{Obtaining an image}
Time to obtain some images!
\begin{itemize}
\item Image the fluorescent sample card.
\textbf{Use low laser power as this sample is very bright}.
Use 1x zoom.
This sample provides information on how uniform the illumination is.
\item Image the $25~\mu m$ pitch copper EM grid at 1x, 2x, and 3x zoom.
How many microns per pixel do you get?
Use any wavelength at low power.
\item Image some pollen grains.
Try focusing up and down through them to get a feeling for the optical sectioning ability of your microscope.
The micrometer advances the sample $500~\mu m$ per revolution.
\item Image a zebrafish larva!
\end{itemize}